The lowest observed group mean is -0.3602 for year group 1,984 to 1,992. The highest is 0.16 for group 1,955 to 1,964, a difference of 0.5202 on the source response scale. Across all 456 numeric records the response median is -0.05.
What was measured
The ELNINO data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as southern oscillation index. It preserves the source scale and its sign. The file contains 4 numeric fields per accepted row.
Spread across the original readings
The two endpoint groups have 108 and 120 observations. Their medians are -0.3 and 0.1, respectively. The figure groups the original entries by the recorded year value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

One row you can check
To check a real observation, take numeric row 21 after the header. Its response is 0. The overall arithmetic mean is -0.1035, so this observation is 0.1035 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 1.3, calculated by subtracting -0.7 from 0.6.
The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.
Worked data
year group | Observations | Mean response | Median response | Minimum response | Maximum response |
|---|---|---|---|---|---|
1,955 to 1,964 | 120 | 0.16 | 0.1 | -2.6 | 1.9 |
1,965 to 1,973 | 108 | -0.03888889 | -0.1 | -2.3 | 2.9 |
1,974 to 1,983 | 120 | -0.1941667 | -0.1 | -3.5 | 2.2 |
1,984 to 1,992 | 108 | -0.3601852 | -0.3 | -3.4 | 1.9 |
Implications for an industrial comparison
Keep the measurement location, observation interval and averaging rule beside the figure. An extreme in a short record cannot supply a design return period. When comparing installations or environmental records, check whether both instruments observed the same temporal and spatial scale.
Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.
Source file and worked data
The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.
Cover photograph by Mark Stebnicki, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.