The senTem.T trace covers -21.694 to 30.6 °C, a temperature span of 52.294 K. The first recorded maximum occurs at 14,821,920 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Outside. The source file places it under Fluid, Sources. We used the 101 stored values for senTem.T over the interval 0 to 31,536,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name bou (Outside), sin (Mass Flow Source T), senTem (Temperature Two Port), senRelHum (Relative Humidity Two Port). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel senRelHum.phi starts at 0.5, ends at 0.735 and has a recorded range of 0.334 to 1 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Source and sink with outside weather data. The simulated senTem.T channel runs from 251.456 to 303.75 K over 31,536,000 seconds.
Source and sink with outside weather data. The simulated senTem.T channel runs from 251.456 to 303.75 K over 31,536,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 14,821,920 to 15,137,280 seconds. Subtracting 303.75 from 279.756 gives -23.994 K. Its location brackets the change within one saved interval of 315,360 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

senTem.T (K)

senRelHum.phi (source units)

0

293.15

0.5

630720

251.4559

0.6391895

6307200

272.5499

0.6699908

1.26144e+07

282.5501

0.5599915

1.482192e+07

303.75

0.3537026

1.513728e+07

279.7556

0.6233835

1.89216e+07

285.9501

0.7999982

2.52288e+07

279.25

0.7899784

3.1536e+07

267.5002

0.7350125

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.