The sim.Vdir trace ranges from 0.1279 rad to 6.25 rad across 101 saved checkpoints. It begins at 1.4661 rad and finishes at 5.5152 rad after 604,800 s of test time. The source identifies the channel scale as rad. Its first saved maximum occurs at 17,600,544 s.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named OutsideAir. The source file places it under Fluid, Sources. We used the 101 stored values for sim.Vdir over the interval 17,280,000 to 17,884,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name west (Outside Air), north (Outside Air), south (Outside Air), east (Outside Air). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The two named channels have separate paths in the model. sim.Vdir begins at 1.4661 and ends at 5.5152. east.pWin begins at 2.1007 and ends at −0.21325. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 17,558,208 to 17,564,256 seconds. Subtracting 0.1279 from 6.192 gives 6.064 source units. Its location brackets the change within one saved interval of 6,048 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

sim.Vdir (rad)

east.pWin (Pa)

1.728e+07

1.466077

2.100672

1.740096e+07

2.639736

-0.8623363

1.752192e+07

5.796288

-2.766955

1.755821e+07

0.1279027

-0.2277945

1.756426e+07

6.191584

-0.3781387

1.760054e+07

6.250004

-1.647918

1.764288e+07

5.687044

-1.832525

1.776384e+07

4.272642

-1.497729

1.78848e+07

5.515241

-0.213246

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, sim.Vdir uses rad and east.pWin uses Pa. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Checking the two recorded channels

At 17,564,256 s, sim.Vdir reads 6.1916 rad and east.pWin reads -0.37814 Pa. Across the run, the second channel ranges from -8.0352 Pa to 2.1007 Pa. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.