The recorded solarThermal.senTSup.T temperature spans 20 °C to 25.973 °C in this simulation. That is a change of 5.9726 K. The first saved maximum occurs at 43,200 s. The source trace and download retain absolute temperatures in kelvin.
The system being tested
The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named SolarThermalCollector. The source file places it under Fluid, Solar, Thermal. We used the 101 stored values for solarThermal.senTSup.T over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 4 recorded variables. Alongside the primary output there are solarThermal.solarThermalEfficiency.Q_flow, solarThermal.solarThermalEfficiency.T_col, solarThermal.solarThermalEfficiency.T_air, solarThermal.senTSup.T. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
At 43,200 s, solarThermal.senTSup.T is 299.123 K and solarThermal.solarThermalEfficiency.T_col is 296.136 K. Subtracting the second value from the first gives 2.9863 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 63,936 to 64,800 seconds. Subtracting 294.389 from 294.029 gives -0.3594 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | solarThermal.senTSup.T (K) | solarThermal.solarThermalEfficiency.T_col (K) |
|---|---|---|
0 | 293.15 | 293.15 |
17280 | 293.6083 | 293.3792 |
34560 | 298.3914 | 295.7707 |
43200 | 299.1226 | 296.1363 |
51840 | 298.0743 | 295.6122 |
63936 | 294.3885 | 293.7693 |
64800 | 294.0291 | 293.5896 |
69120 | 293.2474 | 293.1987 |
86400 | 293.1501 | 293.15 |
What to check on site
Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Units in the source model
The component declarations identify the scale of the exported variables. In this run, solarThermal.solarThermalEfficiency.T_col uses K. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.