The recorded solarThermal.senTSup.T temperature spans 20 °C to 25.973 °C in this simulation. That is a change of 5.9726 K. The first saved maximum occurs at 43,200 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named SolarThermalCollector. The source file places it under Fluid, Solar, Thermal. We used the 101 stored values for solarThermal.senTSup.T over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 4 recorded variables. Alongside the primary output there are solarThermal.solarThermalEfficiency.Q_flow, solarThermal.solarThermalEfficiency.T_col, solarThermal.solarThermalEfficiency.T_air, solarThermal.senTSup.T. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

At 43,200 s, solarThermal.senTSup.T is 299.123 K and solarThermal.solarThermalEfficiency.T_col is 296.136 K. Subtracting the second value from the first gives 2.9863 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

Solar thermal collector. The simulated solarThermal.senTSup.T channel runs from 293.15 to 299.123 K over 86,400 seconds.
Solar thermal collector. The simulated solarThermal.senTSup.T channel runs from 293.15 to 299.123 K over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 63,936 to 64,800 seconds. Subtracting 294.389 from 294.029 gives -0.3594 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

solarThermal.senTSup.T (K)

solarThermal.solarThermalEfficiency.T_col (K)

0

293.15

293.15

17280

293.6083

293.3792

34560

298.3914

295.7707

43200

299.1226

296.1363

51840

298.0743

295.6122

63936

294.3885

293.7693

64800

294.0291

293.5896

69120

293.2474

293.1987

86400

293.1501

293.15

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, solarThermal.solarThermalEfficiency.T_col uses K. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.