The skyCle.skyCle trace ranges from 1.01 to 7.2678 across 101 saved checkpoints. It begins at 1.01 and finishes at 1.1723 after 2,900,000 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named SkyClearness. The source file places it under Boundary Conditions, Solar Irradiation. We used the 101 stored values for skyCle.skyCle over the interval 100,000 to 3,000,000 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 1 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The primary channel spends 7.9% of its saved checkpoints at or above 4.139 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 1.522 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Solar irradiation sky clearness. The simulated skyCle.skyCle channel runs from 1.01 to 7.268 source units over 2,900,000 seconds.
Solar irradiation sky clearness. The simulated skyCle.skyCle channel runs from 1.01 to 7.268 source units over 2,900,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 535,000 to 564,000 seconds. Subtracting 1.01 from 7.268 gives 6.258 source units. Its location brackets the change within one saved interval of 29,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

skyCle.skyCle (source units)

100000

1.01

535000

1.01

564000

7.26783

680000

1.01

1260000

2.351271

1840000

1.015321

2420000

1.01

3000000

1.172267

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.