The solar collector and storage temperatures starts at 20 °C and finishes at 7.636 °C in this reference run. The model stores absolute temperature in kelvin. Its observed minimum and maximum convert to 4.654 °C and 69.106 °C.
What the reference test measures
The Buildings model named FlatPlateWithTank comes from Lawrence Berkeley National Laboratory. The saved result covers simulation time 0 to 86,400 seconds. Industry Applied extracted 101 checkpoints for solCol.vol[9].T and kept the original signed values. The regular output spacing is 864 seconds. The solver may take different internal steps.
The model definition identifies solCol (ASHRAE93), tan (Stratified Enhanced Internal Hex), weaDat (Reader TMY3). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.
Settings to preserve when repeating the experiment
The published test declares rooT.T = 293.15, bou1.T = 288.15. Those numbers use the units and component definitions in the linked model. Start with the declared configuration when reproducing the reference result, then vary one setting at a time. Changing the input waveform and the component response in the same comparison makes it difficult to identify the source of a difference.
Reading the two channels
At 51,840 seconds, solCol.vol[9].T is 341.951 and tan.vol[1].T is 303.784. Subtracting the second channel from the first gives +38.167 K, the largest absolute separation on their common saved grid. The channels have distinct roles in the model, so this difference describes the two traces and is not a calibrated instrument error.
![Solar collector and storage temperatures. In the simulated FlatPlateWithTank case, solCol.vol[9].T ranges from 277.804 to 342.256 K over 86,400 seconds.](https://static.wixstatic.com/media/21e41b_d5213595e05441a69307c25fee7ccea6~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_d5213595e05441a69307c25fee7ccea6~mv2.png)
Reproducing the largest recorded change
Between the stored points at 57,024 and 57,888 seconds, solCol.vol[9].T changes from 326.578 to 319.148. Subtracting the earlier reading gives -7.43 K. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.
The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.
Worked data
Simulation time (s) | solCol.vol[9].T (K) | tan.vol[1].T (K) |
|---|---|---|
0 | 293.15 | 293.15 |
21600 | 277.8418 | 293.1501 |
22464 | 277.8038 | 293.1501 |
43200 | 335.3148 | 298.32 |
52704 | 342.2556 | 304.3438 |
57024 | 326.5783 | 306.556 |
57888 | 319.1483 | 306.759 |
64800 | 288.5187 | 306.7652 |
86400 | 280.7857 | 306.5544 |
Applying the result to an operating site
The collector and the tank have different thermal mass and respond on different timescales. A temperature difference can exist while the circulation pump is stopped. Combine pump state, flow and the two temperatures to calculate useful heat delivered.
For a local engineering comparison, write the measurement boundary, operating duty and instruments into the test record. Select comparable load or weather periods, then compare the measured trace with the simulated quantities. Establish a local acceptance tolerance using the intended duty and measurement uncertainty.
Model and data sources
Model definition. Original numerical reference series. Simulation and plotting script. Source project. Download the worked checkpoints as CSV.