The thermalZone.roo.heaPorAir.T trace covers 7.378 to 30.124 °C, a temperature span of 22.745 K. The first recorded maximum occurs at 568,512 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ThermalZone. The source file places it under Scalable Benchmarks, Building variable air volume, Thermal Zones. We used the 101 stored values for thermalZone.roo.heaPorAir.T over the interval 0 to 604,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name thermalZone (Thermal Zone), weaDat (Reader TMY3). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel thermalZone.weaBus.TDryBul covers 250.348 to 275.054 K. At 568,512 s, the primary value is 303.274 and the companion is 260.37. Their signed difference is 42.904 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Single-zone. The simulated thermalZone.roo.heaPorAir.T channel runs from 280.528 to 303.274 K over 604,800 seconds.
Single-zone. The simulated thermalZone.roo.heaPorAir.T channel runs from 280.528 to 303.274 K over 604,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 30,240 to 36,288 seconds. Subtracting 286.384 from 295.699 gives 9.316 K. Its location brackets the change within one saved interval of 6,048 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

thermalZone.roo.heaPorAir.T (K)

thermalZone.weaBus.TDryBul (K)

0

293.15

260.95

30240

286.3837

263.4906

36288

295.6994

266.586

120960

291.6884

273.51

241920

288.6131

270.35

362880

282.1054

261.5641

483840

293.8216

261.8193

544320

280.5284

250.3481

568512

303.2736

260.3697

604800

288.2854

253.15

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.