The flo.cor.air.vol.T trace covers 20 to 22.584 °C, a temperature span of 2.584 K. The first recorded maximum occurs at 574,560 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named SingleZoneFloorWithHeating. The source file places it under Thermal Zones, Detailed. We used the 101 stored values for flo.cor.air.vol.T over the interval 0 to 604,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name weaDat (Reader TMY3), TSetRoo (Constant), EHeaFlo (Multi Sum), heaAndCon (Single Zone Floor Heater). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel flo.eas.air.vol.T covers 293.15 to 295.187 K. At 574,560 s, the primary value is 295.734 and the companion is 295.144. Their signed difference is 0.5902 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Single-zone floor with heating and control. The simulated flo.cor.air.vol.T channel runs from 293.15 to 295.734 K over 604,800 seconds.
Single-zone floor with heating and control. The simulated flo.cor.air.vol.T channel runs from 293.15 to 295.734 K over 604,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 6,048 seconds. Subtracting 293.15 from 295.156 gives 2.007 K. Its location brackets the change within one saved interval of 6,048 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

flo.cor.air.vol.T (K)

flo.eas.air.vol.T (K)

0

293.15

293.15

6048

295.1565

294.7799

120960

295.1505

295.1583

241920

295.2046

295.1475

362880

295.244

295.1285

483840

295.423

295.1468

574560

295.7343

295.1441

604800

295.3007

294.9555

What to check on site

Separate a calculated setpoint from the damper or fan command and from the measured service delivered. Trend the active operating mode, request, actual flow and zone condition on one clock. A sequence can change state correctly while the terminal fails to reach duty.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.