The PMea.y trace ranges from 0 to 5,279.5 across 101 saved checkpoints. It begins at 0 and finishes at 0 after 172,800 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named SingleSpeed_OnDemandResistiveDefrost. The source file places it under Fluid, direct expansion Systems, Heating, Air Source. We used the 101 stored values for PMea.y over the interval 0 to 172,800 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 8 recorded variables. Alongside the primary output there are TOutDegC.Celsius, TOutEPlu.y, XConOut.y, XConOutEPlu.y, Q_flowMea.y. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The two named channels have separate paths in the model. PMea.y begins at 0 and ends at 0. PEPlu.y begins at 0 and ends at 0. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 153,792 to 155,520 seconds. Subtracting 5,059 from 0 gives -5,059 source units. Its location brackets the change within one saved interval of 1,728 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

PMea.y (source units)

PEPlu.y (source units)

0

0

0

34560

0

0

69120

0

0

103680

0

0

131328

5279.511

5263

138240

5263.228

5247

153792

5058.528

5074

155520

0

0

172800

0

0

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Checking the two recorded channels

At 155,520 s, PMea.y reads 0 and PEPlu.y reads 0. Across the run, the second channel ranges from 0 to 5,263. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.