The recorded struct.W1.propsBus_a.port_1.m_flow channel spans 1.78e-05 to 0.000453 kg/s in this reference run. It starts at 5.37e-05 and ends at 6.37e-05. The first recorded maximum occurs at 21,698,016 seconds and the first minimum at 23,243,712 seconds.
The system being tested
The KU Leuven IDEAS project publishes the IDEAS test named BuildingO5_Exp1_2Port. The source file places it under Twin Houses. We used the 101 stored values for struct.W1.propsBus_a.port_1.m_flow over the interval 15,000,000 to 23,587,200 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 5 recorded variables. Alongside the primary output there are struct.W40.crackOrOperableDoor.m1_flow, struct.W1.propsBus_a.port_1.m_flow, struct.W7.propsBus_a.port_1.m_flow, struct.W10.propsBus_a.port_1.m_flow, struct.W37.propsBus_a.port_1.m_flow. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The companion channel struct.W7.propsBus_a.port_1.m_flow covers -0.000554 to 0.001254 kg/s. At 21,698,016 s, the primary value is 0.000453 and the companion is 0.001254. Their signed difference is -0.000801 kg/s, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
Integrating the signed rate over 8,587,200 seconds gives a net 803.247 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | struct.W1.propsBus_a.port_1.m_flow (kg/s) | struct.W7.propsBus_a.port_1.m_flow (kg/s) |
|---|---|---|
1.5e+07 | 5.371186e-05 | 0.0002364216 |
1.671744e+07 | 7.600593e-05 | 0.000320598 |
1.843488e+07 | 7.600585e-05 | 0.0003205989 |
2.015232e+07 | 8.204936e-05 | 0.000322782 |
2.161214e+07 | 5.493927e-05 | 0.0001853846 |
2.169802e+07 | 0.0004527708 | 0.001253665 |
2.186976e+07 | 0.0001102755 | 0.0001336383 |
2.324371e+07 | 1.784023e-05 | 0.0002538217 |
2.35872e+07 | 6.37344e-05 | 0.0002566928 |
What to check on site
Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.