The recorded comparison_W1[1] channel spans -9.9e-05 to 0.000885 source units in this reference run. It starts at 1.43e-05 and ends at 5.68e-05. The first recorded maximum occurs at 21,698,016 seconds and the first minimum at 20,066,448 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named BuildingO5_Exp1_1Port. The source file places it under Twin Houses. We used the 101 stored values for comparison_W1[1] over the interval 15,000,000 to 23,587,200 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 10 recorded variables. Alongside the primary output there are comparison_W40[1], comparison_W40[2], comparison_W1[1], comparison_W1[2], comparison_W7[1]. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The two named channels have separate paths in the model. comparison_W1[1] begins at 1.4349e−05 and ends at 5.6797e−05. comparison_W1[2] begins at 1.1963e−05 and ends at 5.16e−05. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Simulation of experiment 1 for the o5 building with 1-port pressure driven airflow. The simulated comparison_W1[1] channel runs from -9.9e-05 to 0.000885 source units over 8,587,200 seconds.
Simulation of experiment 1 for the o5 building with 1-port pressure driven airflow. The simulated comparison_W1[1] channel runs from -9.9e-05 to 0.000885 source units over 8,587,200 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 21,612,144 to 21,698,016 seconds. Subtracting 1.59e-05 from 0.000885 gives 0.000869 source units. Its location brackets the change within one saved interval of 85,872 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

comparison_W1[1] (source units)

comparison_W1[2] (source units)

1.5e+07

1.434937e-05

1.19625e-05

1.671744e+07

1.434937e-05

1.17e-05

1.843488e+07

1.434937e-05

1.17e-05

2.006645e+07

-9.895665e-05

-0.0001085229

2.015232e+07

1.161452e-05

1.9328e-05

2.161214e+07

1.594144e-05

2.134783e-05

2.169802e+07

0.0008847976

0.000852815

2.186976e+07

0.0001689382

0.000180575

2.35872e+07

5.679738e-05

5.16e-05

What to check on site

Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.