The recorded fin.fraSun channel spans 0 to 1 source units in this reference run. It starts at 0 and ends at 0. The first recorded maximum occurs at 40,608 seconds and the first minimum at 0 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named SideFins. The source file places it under Heat Transfer, Windows. We used the 101 stored values for fin.fraSun over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name weaDat (Reader TMY3), fin (Side Fins), HDirTil (Direct Tilted Surface). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The two named channels have separate paths in the model. fin.fraSun begins at 0 and ends at 0. fin.HDirTil begins at 0 and ends at 0. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 58,752 to 59,616 seconds. Subtracting 0.3253 from 0 gives -0.3253 source units. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | fin.fraSun (source units) | fin.HDirTil (source units) |
|---|---|---|
0 | 0 | 0 |
17280 | 0 | 0 |
34560 | 0.769622 | 368.8929 |
40608 | 1 | 519.1184 |
51840 | 0.744888 | 55.62357 |
58752 | 0.3252669 | 0.3475333 |
59616 | 0 | 0 |
69120 | 0 | 0 |
86400 | 0 | 0 |
What to check on site
Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

