The paired temperature and humidity response comprises two two-byte measurement words, each accompanied by its own CRC byte. Six received payload bytes therefore represent four value bytes and two integrity bytes per complete response. In the worked example, Complete measurement responses 10 gives returned data and crc bytes of 60.

The recorded quantity and the calculated result

Keep three columns in a commissioning export: the original complete measurement responses, the configuration used in the conversion and the resulting returned data and crc bytes. Recompute the result for the lower, middle and upper worked points before interpreting a field difference. A change in range, units or representation can otherwise be mistaken for a change in the process.

Two points to check independently

At 5 the calculated returned data and crc bytes is 30. At 10 it is 60. Subtracting the first output from the second gives 30. These values give two independent checkpoints for a spreadsheet or a logger conversion.

SHT3x measurement frame overhead. Complete measurement responses changes from 1 to 120 and the calculated Returned data and CRC bytes changes from 6 to 720.
SHT3x measurement frame overhead. Complete measurement responses changes from 1 to 120 and the calculated Returned data and CRC bytes changes from 6 to 720. Figure by Industry Applied.

Worked data

Complete measurement responses

Returned data and CRC bytes

1

6

2

12

5

30

10

60

30

180

60

360

120

720

Checking the ends of the working range

The interval from the middle to the upper test point runs from 10 to 120 on the complete measurement responses axis. Its average change in returned data and crc bytes per input unit is 6. This is a two-point slope for that interval. To check a spreadsheet or a gateway calculation, enter 120 in a separate test row and compare its result against 720 at the displayed precision.

Installation and interpretation

Do not discard failed CRCs silently. Preserve an invalid-reading flag and count failed transfers separately from periods with a stable valid value. Bus address, acknowledgement and start or stop events fall outside the byte total plotted here.

For a repeatable verification, capture a small known case and a second case well away from it. Check whether the difference follows the response in the table, then restore the working configuration and repeat one reading. Store a separate status field for missing or invalid input. Substituting zero would make a dropped observation indistinguishable from a legitimate numerical zero.

Implementation and worked data

The source implementation is maintained in the .NET IoT device project. The component notes and manufacturer references document the supported device and its interfaces. Download the worked numerical example.