The signed flow trace gives a net 0.105 kg over 1 s, using the trapezoidal rule between saved samples. The smallest and largest reported rates are -1.223e-12 kg/s and 0.20792 kg/s. Check the positive flow direction in the model before using the sign to describe delivery or return.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named SeriesDp. The source file places it under Fluid, Performance, Pressure Drop. We used the 101 stored values for sin.ports[1].m_flow over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name sou (Boundary p T), pulse_p (Pulse), sin (Boundary p T). The source declares dp_nominal = 1, m_flow_nominal = 1. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The primary channel spends 50.5% of its saved checkpoints at or above 0.104 kg/s, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 0.105 kg/s. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.
![Series connection with prescribed pressure difference and non-optimised parameters. The simulated sin.ports[1].m_flow channel runs from 0 to 0.2079 kg/s over 1 seconds.](https://static.wixstatic.com/media/21e41b_8485dcdef9c94f3b9b72d5880d8b2190~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_8485dcdef9c94f3b9b72d5880d8b2190~mv2.png)
Reproduce the calculation
Integrating the signed rate over 1 seconds gives a net 0.105 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | sin.ports[1].m_flow (kg/s) |
|---|---|
0 | 0.2079205 |
0.2 | 0.2079205 |
0.4 | 0.2079205 |
0.5 | 0.2079205 |
0.51 | -1.222751e-12 |
0.6 | 0 |
0.8 | 0 |
1 | 0 |
What to check on site
Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

![Series connection with prescribed pressure difference and non-optimised parameters. sin.ports[1].m_flow (kg/s) ranges from −1.2228e−12 to 0.20792 across the recorded simulation time (s) interval of 0 to 1. Bands show the minimum and maximum per group of samples. Crossbars mark the median.](/story-art/f9b8fa4f5de8a919c.webp)