The recorded TEvaIn.y channel spans 297.15 to 302.15 source units in this reference run. It starts at 302.15 and ends at 297.15. The first recorded maximum occurs at 0 seconds and the first minimum at 3,024 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named SensibleHeatRatio. The source file places it under Fluid, direct expansion Systems, Cooling. We used the 101 stored values for TEvaIn.y over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name p (Constant), onOff (Boolean Step), hEvaIn (Ramp), TEvaIn (Ramp). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The two named channels have separate paths in the model. TEvaIn.y begins at 302.15 and ends at 297.15. onOff.y begins at 0 and ends at 1. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Sensible heat ratio. The simulated TEvaIn.y channel runs from 297.15 to 302.15 source units over 3,600 seconds.
Sensible heat ratio. The simulated TEvaIn.y channel runs from 297.15 to 302.15 source units over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 2,484 to 2,520 seconds. Subtracting 301.45 from 301.15 gives -0.3 source units. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

TEvaIn.y (source units)

onOff.y (source units)

0

302.15

0

720

302.15

1

1440

302.15

1

2160

302.15

1

2484

301.45

1

2520

301.15

1

2880

298.15

1

3024

297.15

1

3600

297.15

1

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.