The lowest observed group mean is 3,150 for test id group 2. The highest is 3,200 for group 1, a difference of 50 on the source response scale. Across all 32 numeric records the response median is 3,157.

What was measured

The SPAGON4 data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as wafer thickness. It preserves the source scale and its sign. The file contains 2 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 16 and 16 observations. Their medians are 3,100 and 3,224, respectively. The figure groups the original entries by the recorded test id value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Semiconductor film thickness comparison. The lowest and highest group means are 3,150 and 3,200 on the source response scale.
Semiconductor film thickness comparison. The lowest and highest group means are 3,150 and 3,200 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 17 after the header. Its response is 3,163. The overall arithmetic mean is 3,175, so this observation is -12 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 260.75, calculated by subtracting 3,025 from 3,286.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

test id group

Observations

Mean response

Median response

Minimum response

Maximum response

1

16

3200

3224

2884

3487

2

16

3150

3100.5

2781

3744

Implications for an industrial comparison

Record fixture connections, instrument range, excitation level and temperature alongside the measured result. Repeatability within one setup can remain good even when fixtures differ between laboratories. A useful acceptance run includes both a repeat measurement without disturbing the setup and a repeat after a normal reconnection.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.