The archived response ranges from 80.574 to 1,469. The median is 894.206 and the central half of the measurements extends from 95.854 to 1,328. Those figures use all 37 numeric observations in this source series and retain its original measurement scale.
What was measured
The THURBER data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as electron mobility. It preserves the source scale and its sign. The file contains 2 numeric fields per accepted row.
Spread across the original readings
The tenth percentile is 88.351 and the ninetieth is 1,445. They provide a narrower description of the typical spread than the minimum and maximum. The largest and smallest observed records are separated by 1,388. This is the range of this sample, rather than a guaranteed operating envelope.

One row you can check
To check a real observation, take numeric row 19 after the header. Its response is 894.206. The overall arithmetic mean is 783.21, so this observation is 110.996 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 1,232, calculated by subtracting 95.854 from 1,328.
The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.
Worked data
Percentile | Observed response (source scale) | Number of numeric rows |
|---|---|---|
0 | 80.574 | 37 |
10 | 88.3512 | 37 |
25 | 95.854 | 37 |
50 | 894.206 | 37 |
75 | 1327.543 | 37 |
90 | 1444.935 | 37 |
100 | 1468.705 | 37 |
Implications for an industrial comparison
Record fixture connections, instrument range, excitation level and temperature alongside the measured result. Repeatability within one setup can remain good even when fixtures differ between laboratories. A useful acceptance run includes both a repeat measurement without disturbing the setup and a repeat after a normal reconnection.
Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.
Source file and worked data
The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.
Cover photograph by Peter Xie, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.