The zon.TAir trace covers 9.619 to 20 °C, a temperature span of 10.381 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named EquipmentSchedule. The source file places it under Thermal Zones, Energy Plus 24 2 0, Single Family House. We used the 101 stored values for zon.TAir over the interval 0 to 172,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name schInt (Schedule), intLoaFra (Pulse). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 25.7% of its saved checkpoints at or above 287.96 K, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 286.209 K. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Schedule that overrides a schedule in energy plus. The simulated zon.TAir channel runs from 282.769 to 293.15 K over 172,800 seconds.
Schedule that overrides a schedule in energy plus. The simulated zon.TAir channel runs from 282.769 to 293.15 K over 172,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 1,728 seconds. Subtracting 293.15 from 289.828 gives -3.322 K. Its location brackets the change within one saved interval of 1,728 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

zon.TAir (K)

0

293.15

1728

289.828

34560

287.6759

69120

286.5736

103680

283.2209

110592

282.7691

138240

288.2097

172800

283.5978

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.