Use the five-second periodic measurement interval in this binding. In a 60-second observation window the sensor can provide at most twelve fresh measurements after startup. The logger can capture no more fresh values than either the number produced or its own number of polls. With logger poll interval (s) at 6, the worked result is 10 on the upper bound on fresh results per minute scale.
The recorded quantity and the calculated result
Keep three columns in a commissioning export: the original logger poll interval (s), the configuration used in the conversion and the resulting upper bound on fresh results per minute. Recompute the result for the lower, middle and upper worked points before interpreting a field difference. A change in range, units or representation can otherwise be mistaken for a change in the process.
Two points to check independently
Take the neighbouring worked points 5 and 6 on the input axis. The results are 12 and 10, giving a signed difference of -2. The table preserves the calculated values before display rounding. These are calculated examples under the stated assumptions. They are not readings from a ProSense installation.

Worked data
Logger poll interval (s) | Upper bound on fresh results per minute |
|---|---|
1 | 12 |
2 | 12 |
3 | 12 |
5 | 12 |
6 | 10 |
10 | 6 |
15 | 4 |
30 | 2 |
Checking the ends of the working range
The final interval in this example runs from 6 to 30 on the logger poll interval (s) axis. Its average change in upper bound on fresh results per minute per input unit is -0.3333. This is a two-point slope for that interval. To check a spreadsheet or a gateway calculation, enter 30 in a separate test row and compare its result against 2 at the displayed precision.
Installation and interpretation
Polling faster can repeat the previous reading. A good record includes data-ready state and acquisition time. Treat the calculation as an upper bound because phase, start-up behaviour and missed reads can reduce the actual count.
For a repeatable verification, capture a small known case and a second case well away from it. Check whether the difference follows the response in the table, then restore the working configuration and repeat one reading. Store a separate status field for missing or invalid input. Substituting zero would make a dropped observation indistinguishable from a legitimate numerical zero.
Implementation and worked data
The source implementation is maintained in the .NET IoT device project. The component notes and manufacturer references document the supported device and its interfaces. Download the worked numerical example.