The sen_N.I[3] trace ranges from 0.73485 A to 7.3485 A across 101 saved checkpoints. It begins at 7.3485 A and finishes at 0.73485 A after 1 s of test time. The source identifies the channel scale as A. Its first saved maximum occurs at 0 s.

The model includes unbalanced impedance arrangements with and without a neutral connection. The article’s current trace belongs to a specific phase and sensor. To measure the effect of the neutral, select matching phase currents in the two configurations at the same instant and keep the source conditions fixed.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Impedances. The source file places it under Electrical, AC, Three Phases Unbalanced, Loads. We used the 101 stored values for sen_N.I[3] over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name sou_N (Fixed Voltage N), sen_N (Generalized Sensor N), imp_N (Impedance N), sou (Fixed Voltage). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 29.7% of its saved checkpoints at or above 4.042 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 2.962 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

How a neutral connection affects a simulated unbalanced three-phase load. The simulated sen_N.I[3] channel runs from 0.7348 to 7.348 source units over 1 seconds.
How a neutral connection affects a simulated unbalanced three-phase load. The simulated sen_N.I[3] channel runs from 0.7348 to 7.348 source units over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.25 to 0.26 seconds. Subtracting 7.348 from 6.228 gives -1.121 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

sen_N.I[3] (A)

0

7.348467

0.2

7.348467

0.25

7.348467

0.26

6.227514

0.4

1.986072

0.6

1.006639

0.75

0.7348467

0.8

0.7348467

1

0.7348467

What to check on site

Keep voltage, current, real power and energy distinct. Establish the reference direction at the measurement terminal before interpreting a sign change as import or export. Compare the same load boundary and duration in site data and the simulation.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Units in the source model

The component declarations identify the scale of the exported variables. In this run, sen_N.I[3] uses A. Keep the exact channel name and unit together when exporting data to a historian. Read the component definition.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.