The recorded senWhe.P channel spans 0 to 100 W in this reference run. It starts at 0 and ends at 100. The first recorded maximum occurs at 1 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named VariableSpeedThermalWheels. The source file places it under Fluid, Heat Exchangers, Thermal Wheels. We used the 101 stored values for senWhe.P over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name senWhe (Speed Correction Sensible), uSpe (Ramp), latWhe (Speed Correction Latent), latWheDefMotCur (Speed Correction Latent). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel latWheDefMotCur.P covers 0 to 100 W. At 0.01 s, the primary value is 4.762 and the companion is 31.145. Their signed difference is -26.383 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

S the variable-speed thermal wheels. The simulated senWhe.P channel runs from 0 to 100 W over 1 seconds.
S the variable-speed thermal wheels. The simulated senWhe.P channel runs from 0 to 100 W over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed senWhe.P samples by the trapezoidal rule gives 1.88e-05 kWh over 1 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

senWhe.P (W)

latWheDefMotCur.P (W)

0

0

0

0.01

4.761905

31.14537

0.2

49.18481

37.65042

0.4

63.50889

51.16242

0.6

75

68.55472

0.8

94.11764

84.88198

1

100

100

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

Cover photograph by Jakub Zerdzicki, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.