The dyn.medium.T trace covers 18.262 to 22.396 °C, a temperature span of 4.135 K. The first recorded maximum occurs at 3,600 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ConservationEquation. The source file places it under Fluid, Interfaces. We used the 101 stored values for dyn.medium.T over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name dyn (Conservation Equation), ste (Static Two Port Conservation Equation), mWat_flow (Constant), res1 (Pressure Drop). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel ste.sta_b.T covers 288.37 to 297.93 K. At 1,836 s, the primary value is 292.149 and the companion is 297.93. Their signed difference is -5.781 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

S the conservation equation. The simulated dyn.medium.T channel runs from 291.412 to 295.546 K over 3,600 seconds.
S the conservation equation. The simulated dyn.medium.T channel runs from 291.412 to 295.546 K over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 1,800 to 1,836 seconds. Subtracting 292.044 from 292.149 gives 0.1055 K. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

dyn.medium.T (K)

ste.sta_b.T (K)

0

293.15

288.3699

720

291.6995

288.3699

900

291.4117

288.3699

1440

291.8246

293.15

1800

292.0438

293.15

1836

292.1493

297.9301

2160

293.0174

297.9301

2880

294.5081

297.9301

3600

295.5465

297.9301

What to check on site

Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.