The hex.sta_b1.T trace covers 5.02 to 5.024 °C, a temperature span of 0.004089 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named HexElementLatentLoop. The source file places it under Fluid, Heat Exchangers. We used the 101 stored values for hex.sta_b1.T over the interval 0 to 50 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name sin_2 (Boundary p T), sin_1 (Boundary p T), sou (Mass Flow Source T), hex (Hex Element Latent). The source declares mW_flow_nominal = 0.1, mA_flow_nominal = 0.14. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel hex.sta_b2.T covers 290.185 to 290.598 K. At 0 s, the primary value is 278.174 and the companion is 290.598. Their signed difference is -12.423 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

S the basic element that is used to built heat exchanger. The simulated hex.sta_b1.T channel runs from 278.17 to 278.174 K over 50 seconds.
S the basic element that is used to built heat exchanger. The simulated hex.sta_b1.T channel runs from 278.17 to 278.174 K over 50 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 0.5 seconds. Subtracting 278.174 from 278.174 gives -0.000397 K. Its location brackets the change within one saved interval of 0.5 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

hex.sta_b1.T (K)

hex.sta_b2.T (K)

0

278.1742

290.5977

0.5

278.1738

290.5563

10

278.1706

290.233

20

278.1702

290.1902

25

278.1701

290.1865

30

278.1701

290.1853

40

278.1701

290.1847

50

278.1701

290.1847

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.