The ntu[1] trace ranges from 0.010101 to 1.1899 across 101 saved checkpoints. It begins at 0.010101 and finishes at 1.1899 after 1 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named EpsilonNTUZ. The source file places it under Fluid, Heat Exchangers. We used the 101 stored values for ntu[1] over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 6 recorded variables. Alongside the primary output there are ntu[1], ntu[6], ntu[3], ntu[2], ntu[4]. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The reference model evaluates the effectiveness and the inverse transfer-unit relationship for several flow arrangements. Check a forward and inverse calculation at the same heat-capacity-rate ratio and flow arrangement. Results indexed for different arrangements answer separate questions, even when both columns are dimensionless.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.99 to 1 seconds. Subtracting 1.163 from 1.19 gives 0.02731 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

ntu[1] (source units)

ntu[2] (source units)

0

0.01010135

0.01009999

0.2

0.1219305

0.1213415

0.4

0.2666379

0.2609661

0.6

0.4644104

0.4386773

0.8

0.7502063

0.6652625

0.99

1.162629

0.9390165

1

1.189935

0.9554076

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Checking the two recorded channels

At 1 s, ntu[1] reads 1.1899 and ntu[2] reads 0.95541. Across the run, the second channel ranges from 0.0101 to 0.95541. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.