The senTem2a.T trace covers 19.96 to 20.85 °C, a temperature span of 0.8903 K. The first recorded maximum occurs at 36 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named HeaterCooler_u. The source file places it under Fluid, Interfaces. We used the 101 stored values for senTem2a.T over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name hea1 (Heater Cooler u), TDb (Constant), u (Ramp), hea2 (Heater Cooler u). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel senTem2b.T covers 290.93 to 295.5 K. At 72 s, the primary value is 293.643 and the companion is 291.036. Their signed difference is 2.607 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

S a heat exchanger model with reverse flow. The simulated senTem2a.T channel runs from 293.11 to 294 K over 3,600 seconds.
S a heat exchanger model with reverse flow. The simulated senTem2a.T channel runs from 293.11 to 294 K over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 36 seconds. Subtracting 293.15 from 294 gives 0.8504 K. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

senTem2a.T (K)

senTem2b.T (K)

0

293.15

293.15

36

294.0004

291.4998

468

293.1102

291.3415

720

293.1102

291.6761

1440

293.1102

292.6321

2160

293.1102

293.5882

2880

293.1102

294.5442

3600

293.1102

295.5002

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.