The seg.TBouCon.port.T trace covers 10 to 15.487 °C, a temperature span of 5.487 K. The first recorded maximum occurs at 157,680,000 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named BoreholeSegment. The source file places it under Fluid, Geothermal, Boreholes. We used the 101 stored values for seg.TBouCon.port.T over the interval 0 to 157,680,000 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name seg (Borehole Segment), sou_1 (Boundary p T), sin_2 (Boundary p T). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel seg.soi.T[1] covers 283.15 to 297.042 K. At 1,576,800 s, the primary value is 283.588 and the companion is 294.587. Their signed difference is -10.999 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 1,576,800 to 3,153,600 seconds. Subtracting 283.588 from 284.419 gives 0.831 K. Its location brackets the change within one saved interval of 1,576,800 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | seg.TBouCon.port.T (K) | seg.soi.T[1] (K) |
|---|---|---|
0 | 283.15 | 283.15 |
1576800 | 283.5884 | 294.5873 |
3153600 | 284.4194 | 295.0296 |
3.1536e+07 | 287.0655 | 296.3643 |
6.3072e+07 | 287.7763 | 296.674 |
9.4608e+07 | 288.168 | 296.8422 |
1.26144e+08 | 288.4353 | 296.9562 |
1.5768e+08 | 288.6366 | 297.0418 |
What to check on site
The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.