The signed flow trace gives a net 5.321e-12 kg over 1 s, using the trapezoidal rule between saved samples. The smallest and largest reported rates are -0.071429 kg/s and 0.071429 kg/s. Check the positive flow direction in the model before using the sign to describe delivery or return.

The input is a mass-flow rate and the response is a convective thermal resistance. Use the paired observations to examine how the resistance depends on flow. Comparing two configurations requires the same fluid state and geometry because those also enter the underlying heat-transfer calculation.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ConvectionResistance. The source file places it under Fluid, Geothermal, Boreholes. We used the 101 stored values for m_flow over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name m_flow (Mass Flow Rate), R (Thermal Resistance). The source declares m_flow_nominal = 3000/10/4200. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 0.21 s, m_flow reads -0.041429 kg/s and R reads 0.0037376. Across the run, the second channel ranges from 0.0024173 to 0.20049. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.

How to read a borehole convection-resistance test. The simulated m_flow channel runs from -0.07143 to 0.07143 kg/s over 1 seconds.
How to read a borehole convection-resistance test. The simulated m_flow channel runs from -0.07143 to 0.07143 kg/s over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 1 seconds gives a net 0 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

m_flow (kg/s)

R (source units)

0

-0.07142857

0.002417307

0.2

-0.04285714

0.003637565

0.21

-0.04142857

0.00373757

0.4

-0.01428572

0.008760074

0.6

0.01428571

0.008760076

0.8

0.04285714

0.003637565

1

0.07142857

0.002417307

What to check on site

The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.