The recorded boxWitExpDam.yDam channel spans 0.01667 to 0.2824 source units in this reference run. It starts at 0.01667 and ends at 0.2824. The first recorded maximum occurs at 3,600 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named RoomVAV. The source file places it under variable air volume Reheat, Controls. We used the 101 stored values for boxWitExpDam.yDam over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name boxWitExpDam (Room variable air volume), heaSet (Constant), cooSet (Constant), ram (Ramp). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel boxWitPreIndDam.yDam covers 0.15 to 0.5722 source units. At 3,600 s, the primary value is 0.2824 and the companion is 0.5722. Their signed difference is -0.2898 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Room variable air volume controller. The simulated boxWitExpDam.yDam channel runs from 0.01667 to 0.2824 source units over 3,600 seconds.
Room variable air volume controller. The simulated boxWitExpDam.yDam channel runs from 0.01667 to 0.2824 source units over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 3,564 to 3,600 seconds. Subtracting 0.2657 from 0.2824 gives 0.01669 source units. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

boxWitExpDam.yDam (source units)

boxWitPreIndDam.yDam (source units)

0

0.01666667

0.3

720

0.08833162

0.3

1440

0.07266556

0.15

2160

0.09050278

0.15

2880

0.1385142

0.15

3564

0.2657154

0.5265657

3600

0.2824028

0.5722424

What to check on site

Compare fuel or electrical input with useful heat at a declared delivery boundary. Include the warm-up interval and any period on standby. Separate a temperature setpoint from the measured outlet and keep auxiliary energy in a stated part of the balance.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.