The lowest observed group mean is 4.323 for time (in days group 0 to 1. The highest is 11.541 for group 42 to 56, a difference of 7.218 on the source response scale. Across all 88 numeric records the response median is 10.265.

What was measured

The ROSSIT15 data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as initial seam strength. It preserves the source scale and its sign. The file contains 5 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 24 and 16 observations. Their medians are 4.76 and 10.95, respectively. The figure groups the original entries by the recorded time (in days value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Roof-seam tape strength. The lowest and highest group means are 4.323 and 11.541 on the source response scale.
Roof-seam tape strength. The lowest and highest group means are 4.323 and 11.541 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 7 after the header. Its response is 10.28. The overall arithmetic mean is 9.298, so this observation is 0.9819 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 3.348, calculated by subtracting 8.545 from 11.893.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

time (in days group

Observations

Mean response

Median response

Minimum response

Maximum response

0 to 1

24

4.322917

4.76

0

9.63

3 to 14

24

10.54333

10.36

7.57

13.2

21 to 35

24

11.5325

11.195

9.92

13.77

42 to 56

16

11.54125

10.95

9.74

13.82

Implications for an industrial comparison

Compare the specimen geometry, preparation, loading direction, conditioning and endpoint before using this distribution in a materials decision. Failure observations from a controlled test do not directly provide a field failure probability. A comparison with current production also needs the number of specimens withdrawn before the stated endpoint.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.