The published intWitRes1.y signal spans -2.75 to -1 source signal units in the reference run. It starts at -2 and finishes at -1.8. The signed change between those endpoint samples is +0.2 source signal units.
What the reference test measures
The Buildings model named IntegratorWithReset comes from Lawrence Berkeley National Laboratory. The saved result covers simulation time 0 to 1 seconds. Industry Applied extracted 101 checkpoints for intWitRes1.y and kept the original signed values. The regular output spacing is 0.01 seconds. The solver may take different internal steps.
The model definition identifies intDef (Integrator With Reset), intWitRes1 (Integrator With Reset), intWitRes2 (Integrator With Reset). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.
Settings to preserve when repeating the experiment
The published test declares intDef.y_start = -2, intWitRes1.y_start = -2, intWitRes1.k = 0.5. Those numbers use the units and component definitions in the linked model. Start with the declared configuration when reproducing the reference result, then vary one setting at a time. Changing the input waveform and the component response in the same comparison makes it difficult to identify the source of a difference.
Reading the two channels
At 0.4 seconds, intWitRes1.y is -1.2 and intDef.y is -0.2. Subtracting the second channel from the first gives -1 source signal units, the largest absolute separation on their common saved grid. The channels have distinct roles in the model, so this difference describes the two traces and is not a calibrated instrument error.

Reproducing the largest recorded change
Between the stored points at 0.2 and 0.21 seconds, intWitRes1.y changes from -1 to -2.15. Subtracting the earlier reading gives -1.15 source signal units. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.
The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.
Worked data
Simulation time (s) | intWitRes1.y (signal units) | intDef.y (signal units) |
|---|---|---|
0 | -2 | -2 |
0.2 | -1 | -2.980226e-08 |
0.21 | -2.15 | -2.1 |
0.25 | -1.95 | -1.7 |
0.5 | -1.9 | -1.4 |
0.75 | -1.85 | -1.1 |
0.81 | -2.75 | -2.7 |
1 | -1.8 | -0.8 |
Applying the result to an operating site
Store the reset event with the total. A sudden drop in an accumulator can represent an intentional reset rather than a negative process flow. A historian needs the previous total, reset value and event time to construct a continuous audit record.
For an Australian monitoring project, write the intended sample interval, timestamp convention, tag units and missed-update policy into the acceptance record. Re-run this comparison on the installed signal path and retain the raw export so a later dashboard change can be checked against the same baseline.