The lowest observed group mean is 10.764 for position along tube group 3.505. The highest is 25.404 for group 6.532, a difference of 14.64 on the source response scale. Across all 180 numeric records the response median is 14.892.
What was measured
The KAUL2 data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as refrigerant temperature. It preserves the source scale and its sign. The file contains 2 numeric fields per accepted row.
Spread across the original readings
The two endpoint groups have 30 and 30 observations. Their medians are 10.764 and 25.404, respectively. The figure groups the original entries by the recorded position along tube value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

One row you can check
To check a real observation, take numeric row 124 after the header. Its response is 16.129. The overall arithmetic mean is 16.372, so this observation is -0.2426 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 8.285, calculated by subtracting 11.985 from 20.27.
The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.
Worked data
position along tube group | Observations | Mean response | Median response | Minimum response | Maximum response |
|---|---|---|---|---|---|
3.505 | 30 | 10.76402 | 10.76358 | 10.7275 | 10.7965 |
4.104 | 30 | 11.98587 | 11.98495 | 11.95015 | 12.02284 |
4.714 | 30 | 13.59458 | 13.59426 | 13.54746 | 13.6557 |
5.325 | 30 | 16.19767 | 16.1868 | 16.12929 | 16.26831 |
5.938 | 30 | 20.28505 | 20.2741 | 20.12006 | 20.47307 |
6.532 | 30 | 25.40416 | 25.40403 | 25.04735 | 25.78489 |
Implications for an industrial comparison
Keep the measurement location, observation interval and averaging rule beside the figure. An extreme in a short record cannot supply a design return period. When comparing installations or environmental records, check whether both instruments observed the same temporal and spatial scale.
Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.
Source file and worked data
The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.
