The recorded zonSur.TGarAir.y channel spans 271.162 to 292.777 source units in this reference run. It starts at 276.673 and ends at 274.064. The first recorded maximum occurs at 1,425,600 seconds and the first minimum at 622,080 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named SurfaceComparison. The source file places it under Thermal Zones, Energy Plus 24 2 0, Surface Comparison. We used the 101 stored values for zonSur.TGarAir.y over the interval 0 to 2,592,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name refSur (Reference Surfaces), zonSur (Zone Surfaces). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel refSur.TGarAir.y covers 271.803 to 293.374 source units. At 2,306,880 s, the primary value is 285.865 and the companion is 286.677. Their signed difference is -0.8121 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reference surfaces and zone surfaces. The simulated zonSur.TGarAir.y channel runs from 271.162 to 292.777 source units over 2,592,000 seconds.
Reference surfaces and zone surfaces. The simulated zonSur.TGarAir.y channel runs from 271.162 to 292.777 source units over 2,592,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 803,520 to 829,440 seconds. Subtracting 278.584 from 290.831 gives 12.247 source units. Its location brackets the change within one saved interval of 25,920 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

zonSur.TGarAir.y (source units)

refSur.TGarAir.y (source units)

0

276.673

276.673

518400

276.4154

276.974

622080

271.1616

271.8026

803520

278.5835

279.1077

829440

290.8306

291.502

1036800

282.3005

282.8112

1425600

292.7766

293.3735

1555200

286.9323

287.382

2073600

285.1175

285.5948

2592000

274.064

274.5897

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.