The recorded multizone.TAir[1] channel spans 293.134 to 294.184 source units in this reference run. It starts at 293.15 and ends at 293.15. The first recorded maximum occurs at 224,640 seconds and the first minimum at 630,720 seconds.
The system being tested
The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named MultizoneEquipped. The source file places it under Thermal Zones, Reduced Order. We used the 101 stored values for multizone.TAir[1] over the interval 0 to 864,000 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name weaDat (Reader TMY3), tableInternalGains (Combi Time Table), sine (Sine), gain (Gain). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The two named channels have separate paths in the model. multizone.TAir[1] begins at 293.15 and ends at 293.15. multizone.TAir[2] begins at 293.15 and ends at 293.15. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.
![Reduced order multizone equipped. The simulated multizone.TAir[1] channel runs from 293.134 to 294.184 source units over 864,000 seconds.](https://static.wixstatic.com/media/21e41b_e88407e3ea9448f386e3e7609f2a155a~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_e88407e3ea9448f386e3e7609f2a155a~mv2.png)
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 224,640 to 233,280 seconds. Subtracting 294.184 from 293.405 gives -0.7786 source units. Its location brackets the change within one saved interval of 8,640 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | multizone.TAir[1] (source units) | multizone.TAir[2] (source units) |
|---|---|---|
0 | 293.15 | 293.15 |
172800 | 293.1499 | 293.1499 |
224640 | 294.1837 | 294.3206 |
233280 | 293.4051 | 293.928 |
345600 | 293.1498 | 293.1498 |
518400 | 293.1499 | 293.1499 |
630720 | 293.1344 | 293.1341 |
691200 | 293.1498 | 293.1497 |
864000 | 293.1498 | 293.1498 |
What to check on site
Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

![Reduced order multizone equipped. multizone.TAir[1] (source units) ranges from 293.13 to 294.18 across the recorded simulation time (s) interval of 0 to 8.64e+05. Bands show the minimum and maximum per group of samples. Crossbars mark the median.](/story-art/8f818bf19224bdf6b.webp)