The recorded multizone.TAir[1] channel spans 293.134 to 294.184 source units in this reference run. It starts at 293.15 and ends at 293.15. The first recorded maximum occurs at 224,640 seconds and the first minimum at 630,720 seconds.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named MultizoneEquipped. The source file places it under Thermal Zones, Reduced Order. We used the 101 stored values for multizone.TAir[1] over the interval 0 to 864,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name weaDat (Reader TMY3), tableInternalGains (Combi Time Table), sine (Sine), gain (Gain). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The two named channels have separate paths in the model. multizone.TAir[1] begins at 293.15 and ends at 293.15. multizone.TAir[2] begins at 293.15 and ends at 293.15. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Reduced order multizone equipped. The simulated multizone.TAir[1] channel runs from 293.134 to 294.184 source units over 864,000 seconds.
Reduced order multizone equipped. The simulated multizone.TAir[1] channel runs from 293.134 to 294.184 source units over 864,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 224,640 to 233,280 seconds. Subtracting 294.184 from 293.405 gives -0.7786 source units. Its location brackets the change within one saved interval of 8,640 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

multizone.TAir[1] (source units)

multizone.TAir[2] (source units)

0

293.15

293.15

172800

293.1499

293.1499

224640

294.1837

294.3206

233280

293.4051

293.928

345600

293.1498

293.1498

518400

293.1499

293.1499

630720

293.1344

293.1341

691200

293.1498

293.1497

864000

293.1498

293.1498

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.