The recorded zoneIntWal.TSensor channel spans 280.273 to 293.15 source units in this reference run. It starts at 293.15 and ends at 280.689. The first recorded maximum occurs at 0 seconds and the first minimum at 550,368 seconds.
The system being tested
The KU Leuven IDEAS project publishes the IDEAS test named RectangularZoneRedeclarationWindows. The source file places it under Buildings, Components. We used the 101 stored values for zoneIntWal.TSensor over the interval 0 to 604,800 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 2 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The primary channel spends 27.7% of its saved checkpoints at or above 286.711 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 284.574 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 120,960 to 127,008 seconds. Subtracting 285.124 from 287.418 gives 2.294 source units. Its location brackets the change within one saved interval of 6,048 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | zoneIntWal.TSensor (source units) |
|---|---|
0 | 293.15 |
120960 | 285.1235 |
127008 | 287.4179 |
241920 | 286.7333 |
362880 | 282.3876 |
483840 | 283.0495 |
550368 | 280.2727 |
604800 | 280.6894 |
What to check on site
Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.