The recorded Zone.TSensor channel spans 281.062 to 293.15 source units in this reference run. It starts at 293.15 and ends at 281.143. The first recorded maximum occurs at 0 seconds and the first minimum at 550,368 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named RectangularZoneTemplate. The source file places it under Buildings, Components. We used the 101 stored values for Zone.TSensor over the interval 0 to 604,800 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 1 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The primary channel spends 30.7% of its saved checkpoints at or above 287.106 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 285.475 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Rectangular zone template to model a room or building. The simulated Zone.TSensor channel runs from 281.062 to 293.15 source units over 604,800 seconds.
Rectangular zone template to model a room or building. The simulated Zone.TSensor channel runs from 281.062 to 293.15 source units over 604,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 127,008 to 133,056 seconds. Subtracting 287.838 from 289.998 gives 2.161 source units. Its location brackets the change within one saved interval of 6,048 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

Zone.TSensor (source units)

0

293.15

120960

285.882

127008

287.8376

133056

289.9984

241920

287.8924

362880

283.5141

483840

283.731

550368

281.0618

604800

281.1433

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.