The published sigRan.y[2] signal spans -0.657 to 0.932 source signal units in the reference run. It starts at 0 and finishes at 0. The signed change between those endpoint samples is 0 source signal units.
What the reference test measures
The Buildings model named SignalRanker comes from Lawrence Berkeley National Laboratory. The saved result covers simulation time 0 to 1 seconds. Industry Applied extracted 101 checkpoints for sigRan.y[2] and kept the original signed values. The regular output spacing is 0.01 seconds. The solver may take different internal steps.
The model definition identifies sigRan (Signal Ranker), sine (Sine), pulse (Pulse). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.
Settings to preserve when repeating the experiment
The published test declares sine.f = 2, sine.startTime = 0.025, pulse.period = 0.25. Those numbers use the units and component definitions in the linked model. Start with the declared configuration when reproducing the reference result, then vary one setting at a time. Changing the input waveform and the component response in the same comparison makes it difficult to identify the source of a difference.
Reading the two channels
At 0.37 seconds, sigRan.y[2] is -0.657 and sigRan.y[1] is 1. Subtracting the second channel from the first gives -1.657 source signal units, the largest absolute separation on their common saved grid. The channels have distinct roles in the model, so this difference describes the two traces and is not a calibrated instrument error.
![Ranked control input. In the simulated SignalRanker case, sigRan.y[2] ranges from -0.657 to 0.932 source signal units over 1 seconds.](https://static.wixstatic.com/media/21e41b_c0b9863ce96b4e538ca49927eee3d4ef~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_c0b9863ce96b4e538ca49927eee3d4ef~mv2.png)
Reproducing the largest recorded change
Between the stored points at 0 and 0.01 seconds, sigRan.y[2] changes from 0 to 0.582. Subtracting the earlier reading gives +0.582 source signal units. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.
The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.
Worked data
Simulation time (s) | sigRan.y[2] (signal units) | sigRan.y[1] (signal units) |
|---|---|---|
0 | 0 | 1 |
0.01 | 0.5819367 | 1 |
0.02 | 0.9322243 | 1 |
0.25 | 0 | 0.309017 |
0.37 | -0.6569273 | 1 |
0.5 | 0 | 0 |
0.75 | 0 | 0.309017 |
1 | 0 | 0 |
Applying the result to an operating site
An ordered signal can be robust to one extreme channel, depending on which rank drives control. Keep channel identity and any bad-quality flag available. Three values that agree can still share the same common-mode measurement error.
For an Australian monitoring project, write the intended sample interval, timestamp convention, tag units and missed-update policy into the acceptance record. Re-run this comparison on the installed signal path and retain the raw export so a later dashboard change can be checked against the same baseline.
Model and data sources
Model definition. Original numerical reference series. Simulation and plotting script. Source project. Download the worked checkpoints as CSV.
Cover photograph by ed br, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.