The recorded heating.QHeaSys channel spans 0 to 1,922 source units in this reference run. It starts at 0 and ends at 1,877. The first recorded maximum occurs at 1,000 seconds and the first minimum at 0 seconds.
The system being tested
The KU Leuven IDEAS project publishes the IDEAS test named RadiatorHeating. The source file places it under Templates. We used the 101 stored values for heating.QHeaSys over the interval 0 to 100,000 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 2 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The companion channel structure.TSensor[1] covers 293.15 to 297.137 source units. At 1,000 s, the primary value is 1,922 and the companion is 295.827. Their signed difference is 1,626 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 1,000 seconds. Subtracting 0 from 1,922 gives 1,922 source units. Its location brackets the change within one saved interval of 1,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | heating.QHeaSys (source units) | structure.TSensor[1] (source units) |
|---|---|---|
0 | 0 | 293.15 |
1000 | 1922.099 | 295.8267 |
20000 | 1888.547 | 296.7162 |
40000 | 1868.307 | 297.1364 |
60000 | 1880.455 | 296.5196 |
80000 | 1872.028 | 297.0161 |
100000 | 1877.114 | 296.8752 |
What to check on site
Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.