The senTemRad1In.T trace covers 30.014 to 40 °C, a temperature span of 9.986 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named RadiatorEN442_2. The source file places it under Fluid, Heat Exchangers, Radiators. We used the 101 stored values for senTemRad1In.T over the interval 0 to 10,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name sin (Boundary p T), rad1 (Radiator EN442 2), rad2 (Radiator EN442 2), senTemRad1In (Temperature Two Port). The source declares TRoo = 20 + 273.15, Q_flow_nominal = 500, T_a_nominal = 313.15, T_b_nominal = 303.15. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel senTemRad1Out.T covers 293.15 to 303.15 K. At 0 s, the primary value is 313.15 and the companion is 293.15. Their signed difference is 20 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Radiator en442 2. The simulated senTemRad1In.T channel runs from 303.164 to 313.15 K over 10,800 seconds.
Radiator en442 2. The simulated senTemRad1In.T channel runs from 303.164 to 313.15 K over 10,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 3,564 to 3,672 seconds. Subtracting 313.15 from 310.574 gives -2.576 K. Its location brackets the change within one saved interval of 108 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

senTemRad1In.T (K)

senTemRad1Out.T (K)

0

313.15

293.15

2160

313.15

303.15

3564

313.15

303.15

3672

310.5743

302.5305

4320

305.4913

299.7101

6480

303.3491

298.3083

8640

303.1927

298.1864

10800

303.1639

298.1622

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.