The recorded embeddedPipe.dp channel spans 0 to 4,737 Pa in this reference run. It starts at 0 and ends at 0. The first recorded maximum occurs at 1,000 seconds and the first minimum at 0 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named EmbeddedPipeExample. The source file places it under Fluid, Heat Exchangers, Radiant Slab. We used the 101 stored values for embeddedPipe.dp over the interval 0 to 10,000 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 10 recorded variables. Alongside the primary output there are embeddedPipe.dp, embeddedPipe.m_flow, embeddedPipe.R_c, embeddedPipe.R_x_val, embeddedPipe.R_r_val. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel embeddedPipe.m_flow starts at 0, ends at 0 and has a recorded range of 0 to 1 kg/s. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Radiant slab embedded pipe. The simulated embeddedPipe.dp channel runs from 0 to 4,737 Pa over 10,000 seconds.
Radiant slab embedded pipe. The simulated embeddedPipe.dp channel runs from 0 to 4,737 Pa over 10,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 900 to 1,000 seconds. Subtracting 3,837 from 4,737 gives 899.973 Pa. Its location brackets the change within one saved interval of 100 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

embeddedPipe.dp (Pa)

embeddedPipe.m_flow (kg/s)

0

0

0

900

3836.726

0.9

1000

4736.698

1

2000

4736.698

1

4000

0

0

6000

4736.698

1

8000

0

0

10000

0

0

What to check on site

Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.