The radial temperatures in a cylinder starts at 20 °C and finishes at 20.361 °C in this reference run. The model stores absolute temperature in kelvin. Its observed minimum and maximum convert to 20 °C and 20.361 °C.
What the reference test measures
The Buildings model named ConductorSingleLayerCylinder comes from Lawrence Berkeley National Laboratory. The saved result covers simulation time 0 to 36,000 seconds. Industry Applied extracted 101 checkpoints for con.T[1] and kept the original signed values. The regular output spacing is 360 seconds. The solver may take different internal steps.
The model definition identifies TBou (Fixed Temperature). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.
Settings to preserve when repeating the experiment
The published test declares TBou.T = 293.15. Those numbers use the units and component definitions in the linked model. Start with the declared configuration when reproducing the reference result, then vary one setting at a time. Changing the input waveform and the component response in the same comparison makes it difficult to identify the source of a difference.
Reading the two channels
At 36,000 seconds, con.T[1] is 293.511 and con.T[8] is 293.15. Subtracting the second channel from the first gives +0.361 K, the largest absolute separation on their common saved grid. The channels have distinct roles in the model, so this difference describes the two traces and is not a calibrated instrument error.
![Radial temperatures in a cylinder. In the simulated ConductorSingleLayerCylinder case, con.T[1] ranges from 293.15 to 293.511 K over 36,000 seconds.](https://static.wixstatic.com/media/21e41b_fe7c66e743d64109a45e99c07655f208~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_fe7c66e743d64109a45e99c07655f208~mv2.png)
Reproducing the largest recorded change
Between the stored points at 3,600 and 3,960 seconds, con.T[1] changes from 293.15 to 293.206. Subtracting the earlier reading gives +0.056 K. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.
The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.
Worked data
Simulation time (s) | con.T[1] (K) | con.T[8] (K) |
|---|---|---|
0 | 293.15 | 293.15 |
3600 | 293.15 | 293.15 |
3960 | 293.2063 | 293.15 |
9000 | 293.3466 | 293.15 |
18000 | 293.4299 | 293.15 |
27000 | 293.477 | 293.15 |
36000 | 293.5106 | 293.15 |
Applying the result to an operating site
Radial heat flow sees a changing area through the material. Check the node numbering and surface positions in the model before assigning a sensor radius. Two points specified at equal radial intervals do not represent equal material volumes.
For a local engineering comparison, write the measurement boundary, operating duty and instruments into the test record. Select comparable load or weather periods, then compare the measured trace with the simulated quantities. Establish a local acceptance tolerance using the intended duty and measurement uncertainty.
Model and data sources
Model definition. Original numerical reference series. Simulation and plotting script. Source project. Download the worked checkpoints as CSV.