The recorded pum.dpMachine channel spans 310.106 to 9,487 Pa in this reference run. It starts at 310.106 and ends at 9,487. The first recorded maximum occurs at 0.75 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named SpeedControlled_y_pumpCurves. The source file places it under Fluid, Movers. We used the 101 stored values for pum.dpMachine over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name y (Ramp), dp1 (Two Way Linear), dp2 (Two Way Linear), dp3 (Two Way Linear). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel pum1.dpMachine covers 77.507 to 2,373 Pa. At 0.75 s, the primary value is 9,487 and the companion is 2,373. Their signed difference is 7,114 Pa, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Pumps that illustrates the use of the pump curves. The simulated pum.dpMachine channel runs from 310.106 to 9,487 Pa over 1 seconds.
Pumps that illustrates the use of the pump curves. The simulated pum.dpMachine channel runs from 310.106 to 9,487 Pa over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.68 to 0.69 seconds. Subtracting 6,480 from 7,249 gives 769.243 Pa. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

pum.dpMachine (Pa)

pum1.dpMachine (Pa)

0

310.1064

77.50687

0.2

310.1064

77.50687

0.4

610.9759

152.7064

0.6

2602.469

650.4929

0.68

6479.891

1619.749

0.69

7249.134

1812.054

0.75

9487.163

2372.738

0.8

9487.163

2372.738

1

9487.163

2372.738

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.