The recorded pumCstDp.P channel spans 0 to 1,948 W in this reference run. It starts at 0 and ends at 1,722. The first recorded maximum occurs at 368,000 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named FlowDistributionPumpControl. The source file places it under DHC, Loads. We used the 101 stored values for pumCstDp.P over the interval 0 to 400,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name loa (Combi Time Table), minTSet (Constant), reaRep (Real Scalar Replicator), reaRep1 (Real Scalar Replicator). The source declares nLoa = 5, facMul = 10, mLoaHea_flow_nominal = 1, T_aHeaWat_nominal = 273.15 + 40. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel disCstDp.pumFlo.P covers 598.764 to 1,950 W. At 0 s, the primary value is 0 and the companion is 1,734. Their signed difference is -1,734 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Pump head computation in flow distribution. The simulated pumCstDp.P channel runs from 0 to 1,948 W over 400,000 seconds.
Pump head computation in flow distribution. The simulated pumCstDp.P channel runs from 0 to 1,948 W over 400,000 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed pumCstDp.P samples by the trapezoidal rule gives 189.599 kWh over 400,000 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

pumCstDp.P (W)

disCstDp.pumFlo.P (W)

0

0

1734.304

4000

1703.905

1690.501

80000

1687.993

1688.041

160000

1739.36

1739.874

240000

1718.435

1718.822

320000

1813.942

1816.3

368000

1947.755

1950.357

400000

1722.414

1722.659

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

Cover photograph by Mikhail Nilov, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.