The recorded ddp_dy.y channel spans 0 to 226.757 source units in this reference run. It starts at 0 and ends at 226.757. The first recorded maximum occurs at 1 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named PumpCurveDerivatives. The source file places it under Fluid, Movers. We used the 101 stored values for ddp_dy.y over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name sou (Boundary p T), sin (Boundary p T), m_flow (Ramp), pump1 (Speed Controlled y). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The two named channels have separate paths in the model. ddp_dy.y begins at 0 and ends at 226.76. dm_flow_dy.y begins at −0 and ends at 0.31569. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Pump curve derivatives. The simulated ddp_dy.y channel runs from 0 to 226.757 source units over 1 seconds.
Pump curve derivatives. The simulated ddp_dy.y channel runs from 0 to 226.757 source units over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.09 to 0.1 seconds. Subtracting 18.376 from 20.672 gives 2.297 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

ddp_dy.y (source units)

dm_flow_dy.y (source units)

0

0

0

0.09

18.37593

0.02592722

0.1

20.67248

0.02916749

0.2

43.63344

0.06156277

0.4

89.49483

0.1262297

0.6

135.2765

0.1905636

0.8

181.1358

0.2541743

1

226.7566

0.3156911

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.