The lowest observed group mean is 9.587 for laboratory group 6. The highest is 11.267 for group 7, a difference of 1.68 on the source response scale. Across all 7 numeric records the response median is 10.377.

What was measured

The MANDEL30 data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as pentosan measurement for pulp #1. It preserves the source scale and its sign. The file contains 3 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 1 and 1 observations. Their medians are 9.587 and 11.267, respectively. The figure groups the original entries by the recorded laboratory value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Pulp pentosan interlaboratory testing. The lowest and highest group means are 9.587 and 11.267 on the source response scale.
Pulp pentosan interlaboratory testing. The lowest and highest group means are 9.587 and 11.267 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 5 after the header. Its response is 10.377. The overall arithmetic mean is 10.401, so this observation is -0.02414 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 0.6915, calculated by subtracting 10.049 from 10.74.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

laboratory group

Observations

Mean response

Median response

Minimum response

Maximum response

1

1

10.757

10.757

10.757

10.757

2

1

9.98

9.98

9.98

9.98

3

1

10.117

10.117

10.117

10.117

4

1

10.723

10.723

10.723

10.723

5

1

10.377

10.377

10.377

10.377

6

1

9.587

9.587

9.587

9.587

7

1

11.267

11.267

11.267

11.267

Implications for an industrial comparison

A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.

Cover photograph by RDNE Stock project, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.