The recorded pSat channel spans 0.03226 to 102,430 source units in this reference run. It starts at 0.03226 and ends at 102,430. The first recorded maximum occurs at 1 seconds and the first minimum at 0 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named SaturationPressure. The source file places it under Utilities, Psychrometrics, Functions. We used the 101 stored values for pSat over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name T (Temperature), pSat (Absolute Pressure). The source declares TMin = 190, TMax = 373.16. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The primary channel spends 9.9% of its saved checkpoints at or above 51,215 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 13,450 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0.99 to 1 seconds. Subtracting 95,854 from 102,430 gives 6,577 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | pSat (source units) |
|---|---|
0 | 0.03226286 |
0.2 | 6.012001 |
0.4 | 262.5465 |
0.6 | 3515.214 |
0.8 | 23300.27 |
0.99 | 95853.83 |
1 | 102430.4 |
What to check on site
Record the physical quantity and its reference state before checking agreement. A sensor model can include a delay or mixing volume that an algebraic reference omits. Align both acquisition time and location before interpreting a difference as calibration error.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

