The recorded d[1] channel spans 0 to 1,005 source units in this reference run. It starts at 0 and ends at 962.627. The first recorded maximum occurs at 0.33 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named PropyleneGlycolWater. The source file places it under Media, Antifreeze. We used the 101 stored values for d[1] over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 28 recorded variables. Alongside the primary output there are d[6], d[1], d[5], d[4], d[7]. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The two named channels have separate paths in the model. d[1] begins at 0 and ends at 962.63. d[2] begins at 0 and ends at 965.5. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Propylene glycol water. The simulated d[1] channel runs from 0 to 1,005 source units over 1 seconds.
Propylene glycol water. The simulated d[1] channel runs from 0 to 1,005 source units over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.32 to 0.33 seconds. Subtracting 0 from 1,005 gives 1,005 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

d[1] (source units)

d[2] (source units)

0

0

0

0.2

0

0

0.32

0

1009.385

0.33

1004.521

1009.333

0.4

1003.94

1008.269

0.6

996.0013

999.4199

0.8

981.1964

984.2085

1

962.6274

965.5019

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.