The senTemT.T trace covers 20 to 21 °C, a temperature span of 1 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named PropertySource_T. The source file places it under Fluid, Sources. We used the 101 stored values for senTemT.T over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name proSouXi (Property Source T), bouXi (Mass Flow Source T), sin (Boundary ph), proSouT (Property Source T). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel senTemXi.T covers 287.452 to 293.15 K. At 0 s, the primary value is 294.15 and the companion is 287.452. Their signed difference is 6.698 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Property source t. The simulated senTemT.T channel runs from 293.15 to 294.15 K over 1 seconds.
Property source t. The simulated senTemT.T channel runs from 293.15 to 294.15 K over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.49 to 0.5 seconds. Subtracting 294.15 from 293.65 gives -0.5 K. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

senTemT.T (K)

senTemXi.T (K)

0

294.15

287.4524

0.2

294.15

287.4524

0.4

294.15

287.4524

0.49

294.15

287.4524

0.5

293.65

290.3012

0.51

293.15

293.15

0.6

293.15

293.15

0.8

293.15

293.15

1

293.15

293.15

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.