The recorded limPID.y channel spans 0 to 0.759 source units in this reference run. It starts at 0 and ends at 0.557. The first recorded maximum occurs at 10,080 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named To_VolumeFraction. The source file places it under Fluid, Sensors, Conversions. We used the 101 stored values for limPID.y over the interval 0 to 36,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name conMasVolFra (To Volume Fraction), volFra (Constant), senCO2 (Trace Substances), vol (Mixing Volume). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel conVolFlo.y covers 0 to 32.044 source units. At 10,080 s, the primary value is 0.759 and the companion is 32.044. Their signed difference is -31.285 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Problem for conversion. The simulated limPID.y channel runs from 0 to 0.759 source units over 36,000 seconds.
Problem for conversion. The simulated limPID.y channel runs from 0 to 0.759 source units over 36,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 7,560 to 7,920 seconds. Subtracting 0.2882 from 0.4069 gives 0.1187 source units. Its location brackets the change within one saved interval of 360 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

limPID.y (source units)

conVolFlo.y (source units)

0

0

0

7200

0.1702084

7.185958

7560

0.2882195

12.16817

7920

0.4068947

17.1783

10080

0.7590393

32.04384

14400

0.4907686

20.71913

21600

0.5524188

23.32172

28800

0.5574148

23.53262

36000

0.5570104

23.51555

What to check on site

Record the physical quantity and its reference state before checking agreement. A sensor model can include a delay or mixing volume that an algebraic reference omits. Align both acquisition time and location before interpreting a difference as calibration error.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.