The recorded res11.dp channel spans -10,000 to 10,000 Pa in this reference run. It starts at -10,000 and ends at 10,000. The first recorded maximum occurs at 1 seconds and the first minimum at -1 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named PressureDropPartiallyTurbulent. The source file places it under Fluid, Fixed Resistances. We used the 101 stored values for res11.dp over the interval -1 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name sou (Boundary ph), sin (Boundary ph), res11 (Pressure Drop), res12 (Pressure Drop). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel res08.m_flow starts at -3.482, ends at 3.482 and has a recorded range of -3.482 to 3.482 kg/s. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Pressure drop for not fully turbulent flow. The simulated res11.dp channel runs from -10,000 to 10,000 Pa over 2 seconds.
Pressure drop for not fully turbulent flow. The simulated res11.dp channel runs from -10,000 to 10,000 Pa over 2 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.3 to 0.32 seconds. Subtracting 3,000 from 3,200 gives 200 Pa. Its location brackets the change within one saved interval of 0.02 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

res11.dp (Pa)

res08.m_flow (kg/s)

-1

-10000

-3.482202

-0.6

-6000

-2.314062

-0.2

-2000

-0.9608995

0.2

2000

0.9608995

0.3

3000

1.32908

0.32

3200

1.399503

0.6

6000

2.314062

1

10000

3.482202

What to check on site

Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.