The recorded dpControlled_dp.mov.m_flow channel spans 0 to 1.583 kg/s in this reference run. It starts at 0 and ends at 1.583. The first recorded maximum occurs at 2,736 seconds and the first minimum at 0 seconds.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named DpVar. The source file places it under Fluid, Movers, pressure difference Controlled Movers. We used the 101 stored values for dpControlled_dp.mov.m_flow over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 6 recorded variables. Alongside the primary output there are dpControlled_dp.mov.dpMachine, dpControlled_dp.mov.m_flow, m_flow_nominal, dp_nominal, val.y_actual. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel val.y_actual starts at 0, ends at 1 and has a recorded range of 0 to 1 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Pressure difference var. The simulated dpControlled_dp.mov.m_flow channel runs from 0 to 1.583 kg/s over 3,600 seconds.
Pressure difference var. The simulated dpControlled_dp.mov.m_flow channel runs from 0 to 1.583 kg/s over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 3,600 seconds gives a net 3,284 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

dpControlled_dp.mov.m_flow (kg/s)

val.y_actual (source units)

0

0

0

720

1.406252e-06

0

1440

0.7630851

0.2999333

1512

0.8835647

0.3399333

1548

0.9446828

0.3599333

2160

1.434835

0.6999334

2736

1.582576

1

2880

1.582576

1

3600

1.582576

1

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.